Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.612
Filtrar
1.
Cancer Imaging ; 24(1): 46, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556864

RESUMO

BACKGROUND: PSMA PET/CT is the most sensitive molecular imaging modality for prostate cancer (PCa), yet much of the developing world has little or no access to PET/CT. [99mTc]Tc-PSMA scintigraphy (PS) is a cheaper and more accessible gamma camera-based alternative. However, many resource-constrained departments have only a single camera without tomographic or hybrid imaging functionality, and camera time is frequently in high demand. Simplifying imaging protocols by limiting the field of view (FOV) and omitting SPECT/CT or even SPECT may provide a partial solution. The aim was thus to determine the adequacy of PS planar-only and/or SPECT-only imaging protocols with a limited FOV. METHODS: The scans of 95 patients with histologically proven PCa who underwent PS with full-body planar and multi-FOV SPECT/CT were reviewed. The detection rates for uptake in the prostate gland/bed and in metastases were compared on planar, SPECT, and SPECT/CT. The agreement between modalities was calculated for the detection of metastases and for staging. The impact of imaging a limited FOV was determined. RESULTS: Pathological prostatic uptake was seen in all cases on SPECT/CT (excluding two post-prostatectomy patients), 90.3% of cases on SPECT, and 15.1% on planar images (p < 0.001). Eleven (11.7%) patients had seminal vesicle involvement on SPECT/CT, which was undetectable/indistinguishable on planar images and SPECT. The agreement between modalities was moderate to good (κ = 0.41 to 0.61) for the detection of nodal metastases, with detection rates that did not differ significantly (SPECT/CT = 11.6%, SPECT = 8.4%, planar = 5.3%). Detection rates for bone metastases were 14.7% (SPECT/CT) and 11.6% (SPECT and planar). Agreement between modalities for the detection of bone metastases was good (κ = 0.73 to 0.77). Three (3.1%) patients had visceral metastases on SPECT/CT, two of which were detected on SPECT and planar. There was good agreement between modalities for the TNM staging of patients (κ = 0.70 to 0.88). No metastatic lesions were missed on the limited FOV images. CONCLUSION: When PS scintigraphy is performed, SPECT/CT is recommended. However, the lack of SPECT/CT capabilities should not preclude the use of PS in the presence of limited resources, as both planar and SPECT imaging are adequate and will correctly stage most PCa patients. Furthermore, time-based optimisations are achievable by limiting the FOV to exclude the distal lower limbs.


Assuntos
Neoplasias Ósseas , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Região de Recursos Limitados , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias Ósseas/secundário
2.
Phys Med ; 120: 103335, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38555793

RESUMO

PURPOSE: The aim was to investigate the use of multiple small VOIs for kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy. METHOD: The study was based on patient and simulated SPECT images in anthropomorphic geometries. Images were reconstructed using two reconstruction programs (local LundaDose and commercial Hermia) using OS-EM with and without resolution recovery (RR). Five small VOIs were placed to determine the average activity concentration (AC) in each kidney. The study consisted of three steps: (i) determination of the number of iterations for AC convergence based on simulated images; (ii) determination of recovery-coefficients (RCs) for 2 mL VOIs using a separate set of simulated images; (iii) assessment of operator variability in AC estimates for simulated and patient images. Five operators placed the VOIs, using for guidance: a) SPECT/CT with RR, b) SPECT/CT without RR, and c) CT only. For simulated images, time-integrated ACs (TIACs) were evaluated. For patient images, estimated ACs were compared with results of a previous method based on whole-kidney VOIs. RESULTS: Eight iterations and ten subsets were sufficient for both programs and reconstruction settings. Mean RCs (mean ± SD) with RR were 1.03 ± 0.02 (LundaDose) and 1.10 ± 0.03 (Hermia), and without RR 0.91 ± 0.03 (LundaDose) and 0.94 ± 0.03 (Hermia). Most stable and accurate estimates of the AC were obtained using five 2-mL VOIs guided by SPECT/CT with RR, applying them to images without RR, and including an explicit RC for recovery correction. CONCLUSION: The small VOI method based on five 2-mL VOIs was found efficient and sufficiently accurate for kidney dosimetry in [177Lu]Lu-DOTA-TATE therapy.


Assuntos
Compostos Heterocíclicos com 1 Anel , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Rim
3.
Biomed Phys Eng Express ; 10(3)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38527335

RESUMO

Purpose. The aim of this study was to assess the repeatability of the SUV normalized by liver volume (SUVL) between two liver receptor SPECT/CT studies performed on different days in patients with ICG-R15 values within normal range.Methods. 935 patients who underwent liver receptor scintigraphy between January 2010 and August 2018 were included. Patients who underwent liver resection, hepatic arterial embolization or had ICG-R15 >10% between scans were excluded, and 38 patients were finally included in the analysis. The repeatability of SUVL between scans was assessed using the intraclass correlation coefficient (ICC) (1.1) between SUVLmax, SUVLpeak and SUVLmean at the first and second scan and the additive and proportional errors from the Bland-Altman analysis.Results. In ICC (1,1), SUVLmax, SUVLpeak and SUVLmean were all greater than 0.8, indicating almost perfect repeatability; neither additive nor proportional errors were observed in the Bland-Altman analysis.Conclusions. In patients with ICG-R15 values within the normal range, the SUV Liver (SUVL) between two liver receptor SPECT/CT studies performed on different days was repeatability over time. It was suggested that the SUVL of liver receptor scintigraphy could be an indicator that could be used for follow-up over time in the assessment of liver fibrosis.


Assuntos
Fígado , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Fígado/diagnóstico por imagem
4.
Front Endocrinol (Lausanne) ; 15: 1326858, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38449842

RESUMO

Purpose: The purpose of this study was to assess the effectiveness of [99mTc]Tc-HYNIC-ALUG SPECT/CT in the initial staging of patients with newly diagnosed PCa. Methods: A retrospective analysis was conducted on 227 consecutive patients who underwent [99mTc]Tc-HYNIC-ALUG SPECT/CT imaging for the primary staging of newly diagnosed PCa. The presence and location of PSMA-positive lesions were determined, and the maximum standardized uptake values (SUVmax) of the primary prostate tumor were also measured. The metastatic findings and SUVmax were stratified according to International Society of Urological Pathology (ISUP) grade, prostate-specific antigen (PSA) levels, and D'Amico classification. Furthermore, the [99mTc]Tc-HYNIC-ALUG SPECT/CT findings were compared to the histopathological findings in patients who had undergone radical prostatectomy with pelvic lymph node dissection (PLND). Results: Of the 227 patients, 92.1% (209/227) had positive [99mTc]Tc-HYNIC-ALUG SPECT/CT findings. Advanced disease was detected in 38.8% (88/227) of the patients and was positively correlated with increasing ISUP grade and PSA levels. Lymph node metastases (both pelvic and extrapelvic), bone metastases, and visceral metastases were detected in 30.0% (68/227), 25.6% (58/227), and 3.1% (7/227) of the patients, respectively. For the 129 patients who underwent radical prostatectomy with PLND, the sensitivity of [99mTc]Tc-HYNIC-ALUG SPECT/CT in the evaluation of PCa was 90.7% (117/129). The sensitivity, specificity, accuracy, and positive and negative predictive values for detecting pelvic lymph node metastases on [99mTc]Tc-HYNIC-ALUG SPECT/CT were 23.5% (12/51), 93.6% (73/78), 65.9% (85/129), 70.6% (12/17), and 65.2% (73/112), respectively. Among the 209 patients with PSMA-avid primary prostate disease, the SUVmax of the primary prostate tumor was significantly associated with ISUP grade (p<0.0001), PSA levels (p<0.0001), D'Amico classification (p<0.0001), and advanced disease (p<0.0001). Receiver operating characteristic (ROC) analysis revealed that a PSA level >19.8 ng/ml and SUVmax of the primary prostate tumor >7.4 had a sensitivity of 71.6% and 71.6% and specificity of 76.9% and 82.6%, respectively, for detecting metastatic disease. Conclusions: [99mTc]Tc-HYNIC-ALUG SPECT/CT emerges as a valuable imaging tool for the initial staging of newly diagnosed PCa. The presence of advanced disease and the SUVmax of the primary prostate tumor were positively correlated with ISUP grade and PSA levels.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Masculino , Humanos , Estudos Retrospectivos , Metástase Linfática/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
5.
Nucl Med Rev Cent East Eur ; 27(0): 1-5, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38529769

RESUMO

BACKGROUND: Nuclear medicine uses radionuclides in medicine for diagnosis, staging, therapy, and monitoring the response to therapy. The application of radiopharmaceutical therapy for the treatment of certain diseases is well-established, and the field is expanding. Internal dosimetry is multifaceted and includes different workflows, as well as various calculations based on patient- specific dosimetry. AIM: The objective of this study was to introduce the technical issues which might occur during iodine-131 (¹³¹I) dosimetry performed in nuclear medicine departments. MATERIAL AND METHODS: Retrospective analysis was performed on a group of 44 patients with papillary thyroid cancer who between May 2021 and October 2021 underwent a 131I treatment: 80-100 mCi (2200-3700 MBq, based on the previous medical history and stage of the disease). Patients underwent a series of ¹³¹I therapy scans using gamma camera Discovery NM 670 CT. Whole body scan (WBS) was performed 2, 4, 24 and 48 hours after ¹³¹I administration. Additionally, after 24 hours of single photon emission computed tomography/ computed tomography, two fields of view (SPECT/CT 2-FOV) were performed from the mid-head to the bladder. RESULTS: During the dosimetry procedure, several issues arise. Firstly, after receiving therapeutic doses of ¹³¹I, patients should remain in their rooms until the appropriate activity is achieved before being transported to the diagnostic room. Secondly, the walls between examination rooms meet the requirements for accurate diagnosis but not for therapy, leading to the occurrence of artefacts in patients examined behind the wall, potentially influencing the examination results. Thirdly, personnel in the control room also experience additional exposure (10 times greater than in the case of standard diagnostic procedure). CONCLUSIONS: The dosimetry in patients in whom therapeutic procedures are performed with the use of isotopes is mandatory according to Polish and European law, technical issues which occur during the dosimetry procedures might influence the organization of the work in departments.


Assuntos
Radioisótopos do Iodo , Neoplasias da Glândula Tireoide , Humanos , Radioisótopos do Iodo/uso terapêutico , Estudos Retrospectivos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/radioterapia
6.
Front Endocrinol (Lausanne) ; 15: 1359655, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487344

RESUMO

Objective: There is currently no non-invasive examination that can fully determine the diagnosis of osteomyelitis. SPECT/CT tomographic fusion imaging can provide both local metabolic activity and anatomical information to determine the condition and location. This study evaluates the diagnostic efficacy of 99mTc-MDP SPECT/CT in bone infections, compared to MRI. Methods: In this multicenter retrospective study, 363 patients with suspected bone and joint infections or osteomyelitis were included. Participants underwent 99mTc-MDP SPECT/CT and/or MRI examinations, supplemented by pathogenic bacterial cultures and histopathological analysis. Results: Only SPECT/CT was tested in 169 patients, and only MRI was used in 116. 78 people have implemented both inspections and have detailed information. The diagnostic sensitivity and specificity of SPECT/CT for infection were 96% and 92% respectively, with an accuracy of 96%. For MRI, these figures were 88%, 84%, and 87% respectively. Conclusion: This represents the largest global study to date evaluating osteomyelitis and bone infection diagnosis using 99mTc-MDP SPECT/CT tomographic fusion imaging. The findings indicate that 99mTc-MDP SPECT/CT fusion imaging offers superior diagnostic accuracy compared to MRI. This is particularly evident in cases involving metallic implants and chronic infections. 99mTc-MDP SPECT/CT fusion imaging emerges as a highly suitable non-invasive diagnostic modality, facilitating enhanced clinical follow-up and treatment.


Assuntos
Difosfatos , Osteomielite , Humanos , Estudos Retrospectivos , Medronato de Tecnécio Tc 99m , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Imageamento por Ressonância Magnética , Osteomielite/diagnóstico por imagem
7.
Clin Nucl Med ; 49(4): 348-350, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350074

RESUMO

ABSTRACT: A 41-year-old man was admitted to hospital due to sudden loss of consciousness. A regional brain perfusion SPECT/low-dose CT showed abnormal 99m Tc-HMPAO uptake in the right hemisphere frontotemporally without any other supratentorial or infratentorial radiotracer uptake. A neuropathological examination disclosed a middle cerebral artery aneurysm. Presumably, vessel wall fibrosis prevented collapse. Multiple transmural dissections of the fibrotic aneurysmal wall were the source of the subarachnoid hemorrhage. This interesting image shows that radiotracer accumulation in cerebral artery aneurysms can be a diagnostic pitfall in brain death scintigraphy assessment.


Assuntos
Morte Encefálica , Encéfalo , Masculino , Humanos , Adulto , Morte Encefálica/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Transporte Biológico , Neuroimagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
8.
Clin Nucl Med ; 49(4): e179-e181, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350093

RESUMO

ABSTRACT: 99m Tc-PYP/DPD/HDMP cardiac scintigraphy has a pivotal role in the diagnosis of ATTR cardiac amyloidosis. The combined findings of a Perugini visual score of 2 or 3 in the scan and the absence of monoclonal proteins in blood and urine are highly specific for the diagnosis of ATTR cardiac amyloidosis without a tissue biopsy. We report a case of mitral annular and valve calcification accurately identified in the SPECT/CT, but which could be misinterpreted as ATTR cardiac amyloidosis if only acquiring planar and SPECT images.


Assuntos
Amiloidose , Calcinose , Humanos , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão de Fóton Único , Cintilografia , Amiloidose/diagnóstico por imagem
9.
Clin Nucl Med ; 49(4): e184-e185, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38377358

RESUMO

ABSTRACT: A 36-year-old woman with a history of medullary thyroid carcinoma was referred for 99m Tc-HYNIC-FAPI-46 scan. Her calcitonin levels gradually increased after external beam radiation therapy, whereas her CEA levels were stable. A few suspicious tumoral lymphadenopathies were localized to the superior mediastinum. Interestingly, bilateral physiologic breast uptake was noticed, which was presumed to be due to lactation in the past 18 months. To our knowledge, physiologic breast uptake in 99m Tc-HYNIC-FAPI imaging has not been previously reported.


Assuntos
Mama , Lactação , Quinolinas , Feminino , Humanos , Adulto , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Transporte Biológico
10.
Clin Nucl Med ; 49(4): 366-368, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38389218

RESUMO

ABSTRACT: Struma ovarii is a rare form of ovarian teratoma composed entirely or mainly of mature thyroid tissue. A 55-year-old woman with persistent hypogastric pain for 4 months was admitted to our hospital. She had undergone resection of struma ovarii 4 years ago. Contrast-enhanced CT shows multiple significantly enhanced nodules scattered in the abdominopelvic cavity. Pathological examination of the nodule in the left pararenal region demonstrated thyroid-like follicular epithelium. Herein, we present the 99m TcO 4 whole-body scintigraphy SPECT/CT findings of a case of struma ovarii with extensive peritoneal implants metastasis. Then, she was treated with total thyroidectomy and 131 I therapy.


Assuntos
Neoplasias Ovarianas , Neoplasias Peritoneais , Estruma Ovariano , Teratoma , Feminino , Humanos , Pessoa de Meia-Idade , Estruma Ovariano/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Peritoneais/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
11.
J Nucl Cardiol ; 33: 101809, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38307160

RESUMO

BACKGROUND: We employed deep learning to automatically detect myocardial bone-seeking uptake as a marker of transthyretin cardiac amyloid cardiomyopathy (ATTR-CM) in patients undergoing 99mTc-pyrophosphate (PYP) or hydroxydiphosphonate (HDP) single-photon emission computed tomography (SPECT)/computed tomography (CT). METHODS: We identified a primary cohort of 77 subjects at Brigham and Women's Hospital and a validation cohort of 93 consecutive patients imaged at the University of Pennsylvania who underwent SPECT/CT with PYP and HDP, respectively, for evaluation of ATTR-CM. Global heart regions of interest (ROIs) were traced on CT axial slices from the apex of the ventricle to the carina. Myocardial images were visually scored as grade 0 (no uptake), 1 (uptakeribs). A 2D U-net architecture was used to develop whole-heart segmentations for CT scans. Uptake was determined by calculating a heart-to-blood pool (HBP) ratio between the maximal counts value of the total heart region and the maximal counts value of the most superior ROI. RESULTS: Deep learning and ground truth segmentations were comparable (p=0.63). A total of 42 (55%) patients had abnormal myocardial uptake on visual assessment. Automated quantification of the mean HBP ratio in the primary cohort was 3.1±1.4 versus 1.4±0.2 (p<0.01) for patients with positive and negative cardiac uptake, respectively. The model had 100% accuracy in the primary cohort and 98% in the validation cohort. CONCLUSION: We have developed a highly accurate diagnostic tool for automatically segmenting and identifying myocardial uptake suggestive of ATTR-CM.


Assuntos
Neuropatias Amiloides Familiares , Cardiomiopatias , Aprendizado Profundo , Humanos , Feminino , Neuropatias Amiloides Familiares/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cintilografia , Pirofosfato de Tecnécio Tc 99m , Miocárdio , Cardiomiopatias/diagnóstico por imagem , Pré-Albumina
12.
J Craniomaxillofac Surg ; 52(4): 447-453, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38378369

RESUMO

Imaging with bone scans plays an important role in the diagnostic path of patients with unilateral condylar hyperactivity or unilateral condylar hyperplasia (UCH). The aim of this study is to perform a systematic review of the diagnostic performance of the bone SPECT and SPECT/CT scan for the diagnosis of UCH. PubMed, SCOPUS and EMBASE were searched electronically to identify diagnostic accuracy studies that assessed the diagnostic value of bone SPECT and SPECT/CT for the diagnosis of UCH, Meta-analyses were performed with Metadisc 1.4 and 2.0. A total of 14 studies, with a total number of 887 patients, were included in the qualitative analysis and 11 studies qualified for meta-analyses. The pooled sensitivity and specificity for the SPECT scan were 0.814 (95 % CI: 0.639-0.915) and 0.774 (95 % CI: 0.655-0.861), for the SPECT/CT scan these were 0.818 (95 % CI: 0.749-0.874) and 0.901 (95 % CI: 0.840-0.945). The summary receiver operating characteristics of the SPECT scan showed an area under the curve of 0.847 (95 % CI: 0.722-0.972) and that of the SPECT/CT scan was 0.928 (95 % CI: 0.876-0.980). CONCLUSION: Both bone SPECT scan and SPECT/CT scan provide a high diagnostic accuracy for UCH. The added value of the SPECT/CT scan is questionable and given the potential disadvantages of the SPECT/CT scan, including the increased radiation dose and costs, the diagnostic modality of first choice in patients with UCH should be a SPECT scan.


Assuntos
Doenças Ósseas , Doenças Estomatognáticas , Humanos , Hiperplasia/diagnóstico por imagem , Hiperplasia/patologia , Côndilo Mandibular/diagnóstico por imagem , Côndilo Mandibular/patologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Cintilografia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Doenças Ósseas/patologia
14.
Clin Nucl Med ; 49(5): e227-e229, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38377373

RESUMO

ABSTRACT: A 53-year-old man with follicular thyroid carcinoma (FTC) was referred for renal scintigraphy using 99m Tc-DTPA to assess the kidney function. Unexpectedly, the images showed an abnormal uptake of radiotracer in the right pelvic region. It corresponded to the site of metastasis in the right ilium revealed on 131 I SPECT/CT images. The biopsy pathology of the ilium lesion demonstrated follicular thyroid cancer.


Assuntos
Adenocarcinoma Folicular , Neoplasias Ósseas , Neoplasias da Glândula Tireoide , Masculino , Humanos , Pessoa de Meia-Idade , Pentetato de Tecnécio Tc 99m , Tomografia Computadorizada por Raios X , Adenocarcinoma Folicular/diagnóstico por imagem , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia
16.
J Vasc Interv Radiol ; 35(5): 689-698.e3, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246416

RESUMO

PURPOSE: To characterize estimated mean absorbed tumor dose (ADT), objective response (OR), and estimated target dose of hepatocellular carcinoma (HCC) after resin microsphere yttrium-90 (90Y) radioembolization using partition dosimetry. MATERIALS AND METHODS: In this retrospective, single-center study, multicompartment dosimetry of index tumors receiving 90Y radioembolization between October 2015 and June 2022 was performed using a commercial software package and pretreatment technetium-99m macroaggregated albumin single photon emission computed tomography (SPECT)/computed tomography (CT). In total, 101 patients with HCC underwent 102 treatments of 127 index tumors. Patients underwent imaging every 2-3 months after treatment to determine best response per modified Response Evaluation Criteria in Solid Tumors (mRECIST). Best response was defined as the greatest response category per mRECIST and categorized as OR or nonresponse (NR). A Cox proportional hazards model evaluated the probability of tumor OR and progression-free survival using ADT. RESULTS: The median follow-up period was 148 days (interquartile range [IQR], 92-273 days). The median ADT of OR was 141.9 Gy (IQR, 89.4-215.8 Gy) compared with the median ADT of NR treatments of 70.8 Gy (IQR, 42.0-135.3 Gy; P < .001). Only ADT was predictive of response (hazard ratio = 2.79 [95% confidence interval {CI}: 1.44-5.40]; P = .003). At 6 months, an ADT of 157 Gy predicted 90.0% (95% CI: 41.3%-98.3%) probability of OR. At 1 year, an ADT of 157 Gy predicted 91.6% (95% CI: 78.3%-100%) probability of progression-free survival. Partition modeling and delivered activity were predictive of progression (P = .021 and P = .003, respectively). CONCLUSIONS: For HCC treated with resin microspheres, tumors receiving higher ADT exhibited higher rates of OR. An ADT of 157 Gy predicted 90.0% OR at 6 months.


Assuntos
Carcinoma Hepatocelular , Embolização Terapêutica , Neoplasias Hepáticas , Microesferas , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Agregado de Albumina Marcado com Tecnécio Tc 99m , Radioisótopos de Ítrio , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/mortalidade , Estudos Retrospectivos , Radioisótopos de Ítrio/administração & dosagem , Radioisótopos de Ítrio/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/efeitos adversos , Idoso , Embolização Terapêutica/efeitos adversos , Agregado de Albumina Marcado com Tecnécio Tc 99m/administração & dosagem , Resultado do Tratamento , Fatores de Tempo , Planejamento da Radioterapia Assistida por Computador , Idoso de 80 Anos ou mais , Software , Dosagem Radioterapêutica , Adulto
17.
Eur J Nucl Med Mol Imaging ; 51(6): 1516-1529, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38267686

RESUMO

PURPOSE: Accurate dosimetry is critical for ensuring the safety and efficacy of radiopharmaceutical therapies. In current clinical dosimetry practice, MIRD formalisms are widely employed. However, with the rapid advancement of deep learning (DL) algorithms, there has been an increasing interest in leveraging the calculation speed and automation capabilities for different tasks. We aimed to develop a hybrid transformer-based deep learning (DL) model that incorporates a multiple voxel S-value (MSV) approach for voxel-level dosimetry in [177Lu]Lu-DOTATATE therapy. The goal was to enhance the performance of the model to achieve accuracy levels closely aligned with Monte Carlo (MC) simulations, considered as the standard of reference. We extended our analysis to include MIRD formalisms (SSV and MSV), thereby conducting a comprehensive dosimetry study. METHODS: We used a dataset consisting of 22 patients undergoing up to 4 cycles of [177Lu]Lu-DOTATATE therapy. MC simulations were used to generate reference absorbed dose maps. In addition, MIRD formalism approaches, namely, single S-value (SSV) and MSV techniques, were performed. A UNEt TRansformer (UNETR) DL architecture was trained using five-fold cross-validation to generate MC-based dose maps. Co-registered CT images were fed into the network as input, whereas the difference between MC and MSV (MC-MSV) was set as output. DL results are then integrated to MSV to revive the MC dose maps. Finally, the dose maps generated by MSV, SSV, and DL were quantitatively compared to the MC reference at both voxel level and organ level (organs at risk and lesions). RESULTS: The DL approach showed slightly better performance (voxel relative absolute error (RAE) = 5.28 ± 1.32) compared to MSV (voxel RAE = 5.54 ± 1.4) and outperformed SSV (voxel RAE = 7.8 ± 3.02). Gamma analysis pass rates were 99.0 ± 1.2%, 98.8 ± 1.3%, and 98.7 ± 1.52% for DL, MSV, and SSV approaches, respectively. The computational time for MC was the highest (~2 days for a single-bed SPECT study) compared to MSV, SSV, and DL, whereas the DL-based approach outperformed the other approaches in terms of time efficiency (3 s for a single-bed SPECT). Organ-wise analysis showed absolute percent errors of 1.44 ± 3.05%, 1.18 ± 2.65%, and 1.15 ± 2.5% for SSV, MSV, and DL approaches, respectively, in lesion-absorbed doses. CONCLUSION: A hybrid transformer-based deep learning model was developed for fast and accurate dose map generation, outperforming the MIRD approaches, specifically in heterogenous regions. The model achieved accuracy close to MC gold standard and has potential for clinical implementation for use on large-scale datasets.


Assuntos
Octreotida , Octreotida/análogos & derivados , Compostos Organometálicos , Radiometria , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Octreotida/uso terapêutico , Compostos Organometálicos/uso terapêutico , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Radiometria/métodos , Compostos Radiofarmacêuticos/uso terapêutico , Medicina de Precisão/métodos , Aprendizado Profundo , Masculino , Feminino , Método de Monte Carlo , Processamento de Imagem Assistida por Computador/métodos , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/diagnóstico por imagem
18.
Eur J Nucl Med Mol Imaging ; 51(6): 1558-1573, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38270686

RESUMO

PURPOSE: Classical brachytherapy of solid malignant tumors is an invasive procedure which often results in an uneven dose distribution, while requiring surgical removal of sealed radioactive seed sources after a certain period of time. To circumvent these issues, we report the synthesis of intrinsically radiolabeled and gum Arabic glycoprotein functionalized [169Yb]Yb2O3 nanoseeds as a novel nanoscale brachytherapy agent, which could directly be administered via intratumoral injection for tumor therapy. METHODS: 169Yb (T½ = 32 days) was produced by neutron irradiation of enriched (15.2% in 168Yb) Yb2O3 target in a nuclear reactor, radiochemically converted to [169Yb]YbCl3 and used for nanoparticle (NP) synthesis. Intrinsically radiolabeled NP were synthesized by controlled hydrolysis of Yb3+ ions in gum Arabic glycoprotein medium. In vivo SPECT/CT imaging, autoradiography, and biodistribution studies were performed after intratumoral injection of radiolabeled NP in B16F10 tumor bearing C57BL/6 mice. Systematic tumor regression studies and histopathological analyses were performed to demonstrate therapeutic efficacy in the same mice model. RESULTS: The nanoformulation was a clear solution having high colloidal and radiochemical stability. Uniform distribution and retention of the radiolabeled nanoformulation in the tumor mass were observed via SPECT/CT imaging and autoradiography studies. In a tumor regression study, tumor growth was significantly arrested with different doses of radiolabeled NP compared to the control and the best treatment effect was observed with ~ 27.8 MBq dose. In histopathological analysis, loss of mitotic cells was apparent in tumor tissue of treated groups, whereas no significant damage in kidney, lungs, and liver tissue morphology was observed. CONCLUSIONS: These results hold promise for nanoscale brachytherapy to become a clinically practical treatment modality for unresectable solid cancers.


Assuntos
Braquiterapia , Itérbio , Animais , Braquiterapia/métodos , Camundongos , Itérbio/química , Distribuição Tecidual , Nanopartículas/química , Marcação por Isótopo , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Camundongos Endogâmicos C57BL , Goma Arábica/química , Feminino , Glicoproteínas/química , Linhagem Celular Tumoral , Radioisótopos/química , Radioisótopos/uso terapêutico
19.
Clin Nucl Med ; 49(3): 262-264, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38271240

RESUMO

ABSTRACT: Cerebral and muscular metastases from prostatic adenocarcinoma occur rarely. Patients who develop such metastatic pattern exhibit noticeable symptoms. Herein, we present a 68-year-old man diagnosed with metastatic castrate-resistant prostate cancer. The patient received multiple 177 Lu-PSMA cycles. After the last cycle, a posttreatment SPECT/CT suggested disease progression with uncommon metastatic pattern in the right temporal brain lobe and muscles. 68 Ga-PSMA PET/CT and brain MRI confirmed these findings. Surprisingly, the patient remained asymptomatic up until the conclusion of the follow-up, which lasted for 3 months. This case emphasizes the importance of posttreatment scintigraphic imaging when other biomarkers are inconclusive.


Assuntos
Adenocarcinoma , Neoplasias de Próstata Resistentes à Castração , Neoplasias da Próstata , Radioisótopos , Masculino , Humanos , Idoso , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Antígeno Prostático Específico , Lutécio , Adenocarcinoma/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/diagnóstico por imagem , Neoplasias de Próstata Resistentes à Castração/patologia , Compostos Heterocíclicos com 1 Anel , Dipeptídeos , Resultado do Tratamento
20.
J Nucl Cardiol ; 31: 101777, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38237365

RESUMO

OBJECTIVE: To elucidate the value of gated SPECT-MPI using CT attenuation correction (AC) for prediction of pulmonary hypertension (PHT) in coronary patients by estimation of reliability of non-contrast CT in measurement of main pulmonary artery diameter (MPAd) as well as by assessment of potential predictive role of gated parameters as beneficial accessory findings. BACKGROUND: Contrast-enhanced CT is known as an accurate tool for assessment of MPAd to predict PHT. [1] The low-dose non-contrast CT which is used for AC in MPI study, however, has an unclear value in precise vascular diameter measurement; it is also uncertain whether gated parameters could help to predict PHT. METHODS AND PATIENTS: A total of 207 patients, who had a transthoracic echocardiography and MPI with an interval of maximum one month, underwent this retrospective study. PHT was defined as a RVSP ≥36 mmHg by echocardiography; peak tricuspid regurgitation velocity (PTRV) was also calculated to use as a criterion for PHT. Of all subjects, 120 had RVSP ≥ 36 and 87 showed RVSP < 36; there also were 191 and 16 patients with PTRV ≤ 3.4 m/s and >3.4 m/s, respectively. Comparison was made unconnectedly between each group regarding the echocardiography results with the MPI parameters, with and without CT-AC, including MPAd derived from CT as well as RV/LV uptake ratio, shape index and septal wall motion and thickening scores to define the best indicators of PHT. RESULTS: There was a significant association between established benchmark of PHT in echocardiography (RVSP), with MPAd derived from non-contrast CT as well as with LV shape index from gated study and RV/LV uptake ratio acquired from non-AC SPECT-MPI. Also, stress and rest RV/LV uptake ratio, MPAd, LV end-systolic and LV end-diastolic shape indexes are significantly higher in patients with RVSP ≥ 36 mmHg compare to patients with RVSP < 36 mmHg. CONCLUSIONS: Gated-SPECT-MPI using CT-AC can predict PHT by reliable estimation of MPAd as well as by defining RV/LV uptake ratio and shape index, providing an added clinical value for this invaluable modality in cardiac patients.


Assuntos
Hipertensão Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...